Sign In | Join Free | My infospaceinc.com
China Henan Lantian Medical Supplies Co.,Ltd. logo
Henan Lantian Medical Supplies Co.,Ltd.
The company always adheres to the core concept of "fast and accurate, live up to life", and is committed to providing excellent products and services for the society and contributing to the cause of
Active Member

5 Years

Home > Ag Rapid Test Kit >

Coronavirus Disease Ag Rapid Test Kit Usage Manual Interpretation Sample Buffer

Henan Lantian Medical Supplies Co.,Ltd.
Contact Now

Coronavirus Disease Ag Rapid Test Kit Usage Manual Interpretation Sample Buffer

  • 1
  • 2

Brand Name : ZOSBIO

Model Number : 2019-nCoV Ag Saliva/Sputum

Certification : CE BfArm

Place of Origin : China

MOQ : To be negotiated

Price : To be negotiated

Supply Ability : 10000 Kit/Kit per Day

Delivery Time : To be negotiated

Packaging Details : Kit

Product name : 2019-NCoV Ag Rapid Saliva / Sputum Test Usage Manual Interpretation Sample Buffer

Storage conditions : 2℃~30℃

term of validity : eighteen months

Contact Now

2019-NCoV Ag Rapid Saliva / Sputum Test Usage Manual Interpretation Sample Buffer

Intended Use


This kit was used for the qualitative detection of the novel coronavirus antigen in 2019.Was collected from human saliva / sputum samples.
Novel coronavirus is a novel coronavirus that can cause viral pneumonia.The clinical manifestations are fever, fatigue, dry cough, and a few patients have nasal congestion, runny nose, sore throat, diarrhea and other symptoms.Severe patients usually develop dyspnea and / or hypoxemia a week later, and severe patients rapidly develop acute respiratory distress syndrome, infectious shock, metabolic acidosis, and coagulation disorder.
Novel coronavirus antigen was legalized in samples by side flow immunoassay of suspected saliva / sputum.Antigens are usually detected in saliva / sputum samples in the acute phase of the infection.Positive results indicate the presence of viral antigens, but the clinical correlation between patient history and other diagnostic information is also necessary to determine the infection status.Positive results do not exclude bacterial infections or infections associated with other viruses.The detected pathogen may not be the exact cause of the infection.Negative disease results cannot exclude novel coronavirus infection in 2019, and should not be used as the basis for treatment or patient management decisions (including infection control decisions).If the results are negative, the final decision should be determined based on the patient's recent contact history, medical history, and any clinical symptoms and signs consistent with the novel coronavirus, and confirmed by nucleic acid analysis if necessary.

Principle of Detection


This kit is an immunodetection kit based on the principle of the double-antibody sandwich technique.They was sprayed on the binding pad using the labeled 2019 ncov mAb.During the assay, the 2019 ncov Ag in the sample formed an Ag-ab complex with a labeled 2019 ncov monoclonal antibody.Compounds migrate upwards on the membrane by a capillary effect until they are prepackaged on the detection line and captured by another 2019 ncov monoclonal antibody to form a sandwich complex.If 2019 ncov AG is present in the sample, red T stripes appear in the window.Otherwise, it is a negative result.Control line (c) is used for program control.If the tester performs correctly, always display the control line.

Main Components


The kit consisted of a test card, a sample buffer, and a swab.
Test card: composed of aluminum foil bag, desiccant, test paper and plastic card.The paper consists of water absorbent paper, nitrofiber film, sample pad, rubber pad and rubber sheet.2019 nitrocotton membrane T-line (detection line) package-NCOV Ab and c line (QC line) package of goat anti-rat polyclonal antibody, binding pad containing the 2019-NCOV Ab tag.
Sample buffer: phosphate, sodium azo, etc.

Storage Conditions and Validity


The temperature was temporarily maintained at 2 to 30 °C for 18 months.
The aluminum foil bag is valid within 1 hour after opening.
Production batch number: see the label for details.
Validity period: see the label.

Sample Requirements


(1) Saliva sample collection: do not eat or drink chewing gum or tobacco products within 30 minutes after collecting the saliva samples.Put the tip of the tongue against the palate and collect the saliva roots.Place the disposable sterile cotton swab under the saliva sample.The tongue was used for at least 10 seconds, fully immersed in the saliva, and rotated more than 5 times.(See Table 1)
Note: If the saliva samples have not been collected correctly.

Coronavirus Disease Ag Rapid Test Kit Usage Manual Interpretation Sample Buffer

Figure 1 Methodsfor saliva sample collection

Coronavirus Disease Ag Rapid Test Kit Usage Manual Interpretation Sample Buffer

Figure 2 Methods for sputum sample collection

(2) Sputum specimen collection: rinse it with water, cough up the sputum, put it into the specimen bag, and wipe the specimen with a disposable sterile cotton swab.(See Figure 2)
(3) Sample treatment: The collected samples shall be treated with the sample buffer provided in this kit (the samples not processed immediately shall be stored in dry, sterile and sealed containers).From 2 to 8 degrees Celsius to 24 hours, longer than-70 degrees Celsius (but avoid repeated freeze and thaw).

Test Method


Read the instructions carefully before testing.All reagents were put back to room temperature and testing should be performed at room temperature.
Example processing (see Figure 3).
(1) The sample swab is inserted into the sample buffer and rotates the sample rotated about 10 times near the inner wall to dissolve the sample in the solution as much as possible.
(2) Press the swab tip along the inner wall to flow the liquid into the tube, remove the swab and discard the swab.
(3) Cover it with water droplets.

Coronavirus Disease Ag Rapid Test Kit Usage Manual Interpretation Sample Buffer

Figure 3 Sample processing

Coronavirus Disease Ag Rapid Test Kit Usage Manual Interpretation Sample Buffer

Figure 4 Test procedure

2. Test process (see Figure 4).
(1) Remove the test card.
(2) Add the addition of 2 drops (approximately 80L) of the treated sample extract to the sample hole of the test card to start the timer.
(3) Read the card for 15 minutes at room temperature, and the results are invalid after 20 minutes.

Interpretation of Test Results

Description of the test card (see Figure 5):
1. Results: Quality control line (line C line) should be rechecked.
2. Negative results: quality control line (C line), red ribbon, and coloring.
3. Positive results: there are two red stripes in the test line (t line) and the quality control line (C line).

Coronavirus Disease Ag Rapid Test Kit Usage Manual Interpretation Sample Buffer

Figure 5 Interpretation of test results

Limitation of Test Method


1. This product is a qualitative test and is only used to assist in vitro diagnosis.
2. This product is suitable for saliva and sputum samples, and other sample types may have inaccurate or invalid sample results.
3. If the patient does not have sputum samples, a nasopharyngeal swab should be used for testing.
4. Ensure that an appropriate amount of samples is added for testing.Excessive or excessive samples can lead to inaccurate results.
5. The test results of this reagent are for clinical reference only, and should not be used as the only basis for clinical diagnosis and treatment.After a comprehensive evaluation of all clinical and laboratory results, the final diagnosis of the disease was made.

Product Performance Indicators


1. Detection limit: Inactivated sars-cov-2 viral cultures were used in this study.The minimum detection limit was 6,102 tcid50 / ml.
2. Use the company's standard materials for testing, and the test results should meet the requirements of the company's standard materials.
2.1 Qualification rate of positive control: enterprise positive control p1-p5.
2.2 Qualified rate of negative control: our company n1-n10 negative control test is negative.
2.3 Detection limit: reference L1-L3, L1 is negative and L2 and L3 are positive.
2.4 Reproducibility: Both J1 and J2 were 10-fold positive.
3. Cross-reaction: The following microbes and viruses were injected into the samples at the indicated concentrations to assess their potential interference with the 2019 Novel Coronavirus antigen detection program.virus

4. Interference: evaluate the potential interference in the 2019-nCoV Ag testing procedure, and add the following drugs according to the specified concentration.The results showed that the various drugs did not interfere with the detection results of the reagents.

5. Hook effect: No hook effect was observed in the 2019-NCOV inactivated cultures at a high concentration range of 1.0106 TCID50 / mL.
6. Clinical research: RT-PCR sputum reagent was used as a comparative reagent to detect saliva and sputum samples, respectively.For Each sample size (RT-PCR test), 120 positive and negative samples were selected, and secondary testing was performed using the XIUS reagent.The study results are summarized as follows:

Precautions


1. This product is used for in vitro diagnosis.
2. This product is a disposable product and cannot be recycled.
3. Operation strictly follow the reagent instructions and read the instructions carefully before the experiment.
4. Avoid testing in harsh environmental conditions (including high concentration of corrosive gases, such as 84 disinfectant, dust, sodium hypochlorite, acid-alkali, or acetaldehyde, etc.).Laboratory disinfection should be performed after the experiment.

Company profile


Coronavirus Disease Ag Rapid Test Kit Usage Manual Interpretation Sample BufferCoronavirus Disease Ag Rapid Test Kit Usage Manual Interpretation Sample BufferCoronavirus Disease Ag Rapid Test Kit Usage Manual Interpretation Sample BufferCoronavirus Disease Ag Rapid Test Kit Usage Manual Interpretation Sample Buffer
Zhongxiu Science And Technology Co.,Ltd., is a high-tech enterprise engaged in the research and development, production and operation of in vitro diagnostic products. The in vitro diagnostic products developed by the company cover POCT series, microbial series, biochemical series and immune series reagents and supporting instruments.
The company has always adhered to the core concept of "fast and accurate, living up to life", committed to providing society with excellent products and services, and contributing to the cause of human health.


Product Tags:

Coronavirus Disease Ag Rapid Test Kit

      

Buffer Ag Rapid Test Kit

      

Coronavirus Disease rapid ag test kit

      
Quality Coronavirus Disease Ag Rapid Test Kit Usage Manual Interpretation Sample Buffer for sale

Coronavirus Disease Ag Rapid Test Kit Usage Manual Interpretation Sample Buffer Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Henan Lantian Medical Supplies Co.,Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)